Gas engineers shut down boilers at a block of flats in east London after scaffolding and plastic sheeting obstructed boiler flues, creating a risk of carbon monoxide building up inside the flats.
Cadent was called to Finn House, a five-storey block in Bevenden Street, Hoxton, on 3 November after a resident called out a private engineer to look at a boiler. The scaffold had been put up for work on a rooftop extension.
Emergency engineers found scaffold and sealed plastic sheeting across the flues, restricting the air supply and ventilation, the Local Democracy Reporting Service reported. Residents told the reporter that engineers switched off the boilers on the top floor and that most had theirs back on the next day. One resident said she went a week without heating and hot water.
Cadent confirmed the callout to the reporting service and said the obstruction had made the building “unsafe for residents”. The gas network operator said affected meters would stay isolated until the scaffold was altered or removed and the flues could be checked. The report did not name the scaffolding contractor or establish whether the scaffold had since been altered. It did not report any confirmed carbon monoxide exposure.
The Health and Safety Executive’s roof work guidance says crews working near gas flues or extraction vents should identify what they discharge and assess what controls are needed. It says gas flues must not be blocked, covered or dislodged during the work.
For scaffolders, the check starts before the sheeting goes up: identify where the flues and vents are, then agree with the site team how they’ll be kept clear. The HSE also says those responsible for designing and erecting the scaffold must be told before sheeting or netting is added so they can allow for it in the scaffold design.