Safety Alert Issued over defective double couplers

ADVERTISEMENT
  • A Health & Safety alert has been issued jointly by construction firms Kier | BAM (KBJV) over defective double coupler scaffold fittings.

The KBJV safety alert has pointed out an incident when scaffolders were erecting a handrail using tube and fittings that a drop forged double coupler failed when tightened. The coupler was immediately replaced, quarantined and reported by a member of the Kier BAM scaffold team.

The alert continues to read that on initial inspection the coupler had sheared at the gate hinge pin lug. Further inspections took place on random couplers contained in their recent batch delivered to site and it was identified that a number of similar and additional defects were present that included incorrectly positioned lug holes, incorrectly tapped nut threads, incorrectly dyed bolts threads and missing and bent washers.

KBJV claim the couplers were supplied by Altrad Beaver84 and manufactured in China. Markings on the couplers seem to be correct stating EN74-1 Class BL. An investigation is now underway by both KBJV and the supplier.

Click here view and download the warning

KBJV Suggested Immediate Actions

  • Quarantine all tube and fitting scaffold pending visual inspection.
  • Upon visual inspection remove and replace all double couplers with batch number BM0218G
  • Re-inspect the scaffold and confirm with scaffold foreman.

 

SM Newsdesk
SM Newsdeskhttps://www.scaffmag.com
The staff at ScaffMag.com the leading scaffolding site for a digital generation.

Most popular ↑

Saudi firm breaks 27-year-old scaffolding world record

Saudi scaffolding firm Manar Al Omran has set a new Guinness World Record after building a 67.40m free-standing scaffold in Dammam.

CSCS challenges CISRS case for leaving card scheme

CSCS has challenged the reasons for CISRS’s planned departure, while CISRS tells ScaffMag its legal advice and concerns over duplicate cards underpin the decision.

Scaffold Innovations: GapClamp™

  Since the Work at Height Regulations 2005 came into...

SG4:10 We Think The Answer Is Fast Guard™

If Carlsberg made advance guardrails.....  could this be the...

Scottish scaffolding apprentices to compete at ScaffChamp 2026

A team of young scaffolders from Scotland and Northern...

Latest news

Right-to-work rules extend liability through construction supply chains

Contractors face new responsibilities for labour supplied through subcontracting chains as expanded right-to-work rules come into force.
- Advertisement -
More from

Builder fined £120,000 after fatal fall through unsafe floor

W G Carter has been fined £120,000 after carpenter Richard “Felix” Roper suffered fatal injuries in a fall during building work, with HSE pointing to safer access and work sequencing.

Queensland coroner calls for mandatory tower scaffold controls after fatal collapse

A Queensland coroner has called for mandatory additional controls on freestanding tower scaffolds in public places after finding that the industry’s accepted height-to-base rule of thumb was not enough to protect against strong winds.

Scaffold collapses at Sydney site weeks after two workers seriously injured

The scaffold came down at a development on Wattle Street in Ultimo, inner Sydney, shortly before 6:45pm on Saturday,...

Singapore to mandate fire-retardant scaffold netting from 2027

Singapore will require scaffold netting used outside buildings to meet fire-retardant specifications on projects awarded from 1 March 2027.
Latest articles